D-PL-14541-01-00 Scope
SYNLAB Analytics & Services LAG GmbH
Südstraße 7; 03130
Spremberg
|
Brandenburg
+49 3564 5496101
+49 3564 5496105
simone.kleo @ synlab.com
|
A03, A101, A104, A106, A109, A21, A24, A28, B03, B16, B47, B51, RN24, RN25, RN27, RN28, RN35, Anlage |
Diese Akkreditierung gilt für die folgenden Standorte: Südstraße 7 - Schwarze Pumpe, 03130 Spremberg An der Heide Straße 5 - Schwarze Pumpe, 03130 Spremberg Kraftwerk Jänschwalde - Kraftwerkstraße, 03815 Peitz Kraftwerk Schwarze Pumpe - An der alten Ziegelei, 03130 Spremberg Kraftwerk Boxberg - 02943 Boxberg/Oberlausitz Kraftwerk Moorburg - Moorburger Schanze 2, 21079 Hamburg Kraftwerk Lippendorf - Hauptstraße 200, 04575 Neukieritzsch
physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser (Abwasser, Grundwasser, Oberflächenwasser, Deponiesickerwasser, Badegewässern und technischen Wässern (Prozesswässer), Nutzwässer (Kühlwässer)) sowie Schlämmen, Klärschlamm, Sedimenten, Abfall, Stoffen zur Verwertung, Korrosionsprodukten und Ablagerungen in technischen Anlagen, Böden, Holz und Altholz, Staub, Asche, Kalkstein, Gips und gipshaltigen Suspensionen, Schlacke und Bodenluft sowie Deponiegas und Betriebsgasen; ausgewählte biologische und mikrobiologische Untersuchungen von Wasser (Abwasser, Grundwasser, Oberflächenwasser, Badegewässern und technischen Wässern (Prozesswässer)); Untersuchungen von festen und flüssigen Brennstoffen, Sekundärbrennstoffen, Altölen, Mineralölen, Mineralölprodukten, Schmier- und Isolierflüssigkeiten sowie Hydraulikflüssigkeiten; Untersuchung von Luftinhaltsstoffen und Betriebsgasen; ausgewählte mikrobiologische und chemische Untersuchungen gemäß Trinkwasserverordnung; Probennahme von Roh- und Trinkwasser; Probennahme von Wasser (Abwasser, Kühlwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern), von Schlämmen, Klärschlamm, Abfällen und Sedimenten; Probennahme von Luftinhaltsstoffen und Gasen; Probenahme und Untersuchung von Nutzwasser gemäß Verordnung über Verdunstungskühlanlagen, Kühltürme und Nassabscheider - §3 Absatz 8 42. BImSchV 2017; Probenahme und Untersuchung von Abfall zur Ablagerung nach Deponieverordnung Anhang 4; Fachmodule Wasser, Boden und Altlasten sowie Abfall |
this accreditation applies for the following locations: Südstraße 7 - Schwarze Pumpe, 03130 Spremberg An der Heide Straße 5 - Schwarze Pumpe, 03130 Spremberg Kraftwerk Jänschwalde - Kraftwerkstraße, 03815 Peitz Kraftwerk Schwarze Pumpe - An der alten Ziegelei, 03130 Spremberg Kraftwerk Boxberg - 02943 Boxberg/Oberlausitz Kraftwerk Moorburg - Moorburger Schanze 2, 21079 Hamburg Kraftwerk Lippendorf - Hauptstraße 200, 04575 Neukieritzsch
physical, physical-chemical and chemical analysis of water (sewage, ground water, surface water, seepage water of waste disposal sites, bathing water and tchnical water (process water), industrial water (cooling water)) as well as sludges, sewage sludge, sediments, waste, materials for reuse, corrosion products and sediments in tchnical facilities, grounds, wood and matured wood, dust, ashes, limestone, plaster and gypsum based suspensions, cinder and soil gas as well as dump gas and operating gases; selected biological and microbiological analysis of water (sewage, ground water, surface water, bathing water and tchnical water (process water)); analysis of solid and liquid fuels, secondary fuels, waste oils, oils, oil products, lubrication- and insulating as well as hydraulic fluids; analysis of air constituents and operating gases; selected microbiological and chemical analysis according to decree about drinking water; sampling of raw- and drinking water; sampling of water (sewage, cooling water, water from stagnant water, ground water, running water), of sludges, sewage sludge, wastes and sediments; sampling of air constituents and gas; sampling and analysis of industrial water according to regulation over Evaporative cooling equipment, cooling towers and Wet scrubber - §3 distribution 8 42. blmschv 2017; sampling and analysis of waste for deposite according to landfill regulation annex 4; modul water, soil and old neglected deposits of toxic waste as well as waste |
D-PL-13107-01-00 Scope
LADR GmbH Medizinisches Versorgungszentrum Dr. Kramer und Kollegen
Lauenburger Straße 61; 21502
Geesthacht
|
GERMANY
+49 4152 803 0
+49 4152 803 388
m.einhaus @ ladr.de
|
A03, A21, A26, A28, A35, A40, A55, B14, B51, RN24, RN25, RN27, RN35, Anlage |
Probenahme sowie physikalische, physikalisch-chemische, chemische und mikrobiologische Untersuchungen von Wasser (Grundwasser, Oberflächen, Abwasser, Grundwasser, stehenden Gewässern, Fließgewässern sowie Schwimm- und Badebeckenwasser); Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe, Probenahme von Roh- und Trinkwasser, Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV, mikrobiologische, molekularbiologische und immunologische Untersuchungen von Lebensmitteln und Futtermitteln; Probenahme und mikrobiologische Untersuchungen zur Hygienekontrolle im Lebensmittelbereich, mikrobiologische Untersuchungen von Mineral- und Tafelwasser; Fachmodul Wasser; Forensik, Gesundheitsversorgung (Krankenhaushygiene und Infektionsprävention; Arbeits- und Umweltmedizin) Prüfgebiete: Hygiene und Infektionsprävention, Forensische Alkohologie, Forensische Toxikologie im Rahmen der Fahreignungsdiagnostik, Klinische Chemie Probenahme: Im Rahmen der Fahreignungsdiagnostik |
sampling as well as physical, physical-chemical, chemical and microbiological analysis of water (ground water, surfaces, sewage, ground water, stagnant water, running water as well as swim- and bath water); analysis according to decree about drinking water with except of the radioactive substances, sampling of raw- and drinking water, sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv, microbiological, molecular biological and immunological analysis of food and feedings; sampling and microbiological analysis for hygiene control at in relationship with food, microbiological analysis of mineral- and table water; expert modul water; forensic, health care (hygiene and infection prevention; work- and environmental medicine) testing fields: hygiene and infection prevention, forensic blood alcohol, forensic toxicology at within the scope of of the driving fitness diagnostic, clinical chemical sampling: at within the scope of of the driving fitness diagnostic |
D-PL-14533-01-00 Scope
Stadt Schweinfurt Stadtentwässerung Schweinfurt Umweltlabor Schulgasse 13; 97424
Schweinfurt
|
Bayern
+49 9721 79517
+49 9721 79580
w.fuchs @ stadtentwaesserung-sw.de
|
A03, A04, A21, A28, B47, B51, RN24, RN25, RN27, RN28, RN35, Anlage |
physikalische, physikalisch-chemische, chemische und mikrobiologische Untersuchungen von Wasser (Trinkwasser, Grundwasser, Oberflächenwasser, Schwimm- und Badebeckenwasser und Abwasser); physikalische, physikalisch-chemische und chemische Untersuchungen von Böden, Schlämmen, Sedimenten und Abfall; Probenahme von Abwasser, aus Fließgewässern, von Schwimm- und Badebeckenwasser, Wasser aus Grundwasserleitern, Böden, Schlämmen und Abfall; mikrobiologische Untersuchungen und ausgewählte chemische Parameter gemäß Trinkwasserverordnung, Probenahme von Roh- und Trinkwasser; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Fachmodule Wasser und Abfall |
physical, physico-chemical, chemical and microbiological analysis of water (drinking water, ground water, surface water, swim- and bath water and sewage); physical, physico-chemical and chemical analysis of grounds, sludges, sediments and waste; sampling of sewage, from running water, of swim- and bath water, water from ground water, grounds, sludges and waste; microbiological analysis and selected chemical parameter according to decree about drinking water, sampling of raw- and drinking water; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; modul water and waste |
D-PL-19522-01-00 Scope
AECOM Deutschland GmbH Siemensstraße 10; 63263
Neu-Isenburg
|
Sachsen
+49 30 2215 25 164
milos.stevanovic @ aecom.com
|
A03, A09, A10, A100, A101, A102, A113, A14, A28, B47, B51, RN27, RN28, RN29, Anlage |
Die Akkreditierung gilt für die Standorte:
Siemensstraße 10, 63263 Neu-Isenburg Am Handelshof 1, 45127 Essen Germaniastraße 18-20, 12099 Berlin
Probenahme von Wasser (Wasser aus Grundwasserleitern und von Oberflächengewässern), von Böden, Stoffen zur Verwertung und Bausubstanz; ausgewählte physikalisch-chemische Untersuchungen zur Wasserprobenahme; Fachmodule Abfall, Wasser sowie Boden und Altlasten |
the accreditation is valid for the locations:
Siemensstraße 10, 63263 Neu-Isenburg am Handelshof 1, 45127 Essen Germaniastraße 18-20, 12099 Berlin
sampling of water (water from ground water and of surface water), of grounds, materials for reuse and buildings; selected physico-chemical analysis for water sampling; modul waste, water as well as soil and old neglected deposits of toxic waste |
D-PL-19538-01-00 Scope
Chemiepark Bitterfeld-Wolfen GmbH Abteilung Netze / Grundwasser Am Anglerteich 3; 06803
Bitterfeld-Wolfen OT Greppin
|
GERMANY
+49 3493 767 95
+49 3493 727 87
christine.ringler @ chemiepark.de
|
A03, A102, A28, B51, RN27, RN29, Anlage |
Probenahme von Wasser, Abwasser, Wasser aus stehenden Gewässern, Grundwasserleitern und Fließgewässern; physikalisch und physikalisch-chemische Untersuchungen zur Wasserprobenahme; Fachmodul Wasser |
sampling of water, sewage, water from stagnant water, ground water and running water; physico and physical-chemical analysis for water sampling; expert modul water |
D-PL-19488-01-00 Scope
BOLAB Analytik Ingenieurgesellschaft mbH Herzbergstraße 124; 10365
Berlin
|
Berlin
+49 30 2933160
+49 30 2911336
info @ bolab.de
|
A102, A14, B47, RN27, RN28, RN29, Anlage |
Probenahme von Wasser, Abwasser, Wasser aus stehenden Gewässern, Fließgewässern, Grundwasserleitern, von Böden, Abfällen, Stoffen zur Verwertung, Gebäudeschadstoffen, Bausubstanz und Bauabfällen; ausgewählte physikalisch-chemische Untersuchungen zur Wasserprobenahme; Fachmodule Abfall, Wasser sowie Boden und Altlasten |
sampling of water, sewage, water from stagnant water, running water, ground water, of grounds, wastes, materials for reuse, building contaminants, buildings and construction waste; selected physico-chemical analysis for water sampling; modul waste, water as well as soil and old neglected deposits of toxic waste |
D-PL-14171-01-00 Scope
Intertek Food Services GmbH Olof-Palme-Straße 8; 28719
Bremen
|
Bremen
+49 421 657271
+49 421 65727222
ulrich.willers @ intertek.com
|
A03, A21, A24, A26, A28, B14, B47, B51, B63, RN24, RN25, RN27, Anlage, Annex |
Diese Akkreditierung gilt für die Standorte
Olof-Palme-Straße 8, 28719 Bremen Philipp-Reis-Straße 4, 35440 Linden
physikalische, physikalisch-chemische, chemische, mikroskopische, molekularbiologische, mikrobiologische und sensorische Untersuchungen von Lebensmitteln und Futtermitteln; mikrobiologische Untersuchungen von Einrichtungs- und Bedarfsgegenständen im Lebensmittelbereich; mikrobiologische Untersuchungen und ausgewählte chemische Parameter gemäß Trinkwasserverordnung, Probenahme von Roh- und Trinkwasser; physikalische, chemisch-physikalische und chemische Untersuchungen von Wasser (Grundwasser, Abwasser, Sickerwasser), Schlamm, Sedimenten, Abfall, Stoffen zur Verwertung, wässrigen Eluaten und Boden; Probenahme von Abwasser, Abfall und Stoffen zur Verwertung; Fachmodul Wasser |
this accreditation applies for the locations
Olof-Palme-Straße 8, 28719 Bremen Philipp-Reis-Straße 4, 35440 Linden
physical, physico-chemical, chemical, microscopical, molecular biological, microbiological and sensory analysis of foodstuffs and feedstuffs; microbiological analysis of fitment and utensils in the food sector; microbiological analysis and selected chemical parameters in accordance with the German Drinking Water Regulation, sampling of raw and drinking water; physical, chemical-physical and chemical analysis of water (groundwater, waste water, leachate), sludge, sediments, waste, materials for recycling, aqueous eluates and soil; sampling of waste water, waste and materials for recycling; Specialist module for water |
D-PL-19119-01-00 Scope
Umwelt & Baugrund Consult
Schulstraße 23; 51491
Overath
|
Nordrhein-Westfalen
+49 2204 97380
+49 2204 973838
info @ ubc-geotechnik.de
|
A10, A100, A101, A102, A103, A14, A28, A47, B47, B51, RN27, RN28, RN29, RN36, RN37, Anlage |
Probenahme von Wasser, Abwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, von Böden, Abfällen, Stoffen zur Verwertung und Bodenluft; ausgewählte physikalisch-chemische Untersuchungen zur Wasserprobenahme; bodenphysikalische Untersuchungen; Kampfmittelsondierung manuell sowie computergestützt, oberflächennah und in der Tiefe mittels Bohrlochsondierung, baubegleitende Sondierung durch Feuerwerker in Bereichen mit Munitionsverdacht, Vermessung im Rahmen von Kampfmittelsondierungen und -räumungen; Fachmodule Abfall, Wasser sowie Boden und Altlasten |
sampling of water, sewage, water from stagnant water, ground water, running water, of grounds, wastes, materials for reuse and soil gas; selected physico-chemical analysis for water sampling; soil physical analysis; ordnance exploratory manually as well as computer-aided, near surface and in of the depth using exploratory borehole, during construction probing by artificer in fields with ammunition suspected, survey at within the scope of of Ordnance probes and -evictions; modul waste, water as well as soil and old neglected deposits of toxic waste |
D-PL-14035-01-00 Scope
Hessenwasser GmbH & Co. KG Zentrallabor Gräfenhäuser Straße 118; 64293
Darmstadt
|
Hessen
+49 69 254905001
+49 69 254905009
zentrallabor @ hessenwasser.de
|
A03, A21, A28, B14, B51, RN24, RN25, RN27, RN28, RN35, Anlage |
Diese Akkreditierung gilt für die Standorte
Gräfenhäuser Straße 118, 64293 Darmstadt Söhnleinstraße 158, 65201 Wiesbaden Schwanheimer Ufer 167, 60529 Frankfurt am Main
Probenahme sowie physikalische, physikalisch-chemische, chemische, mikrobiologische und biologische Untersuchungen von Wasser; Probenahme sowie physikalische, physikalisch-chemische und chemische Untersuchung von Klärschlamm und Bioabfall; ausgewählte physikalisch-chemische Untersuchung von Boden und Zinkmetall; Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe, Probenahme von Roh- und Trinkwasser; Probenahme und mikrobiologische Untersuchungen von Wasser aus Rückkühlwerken; Probenvorbereitung und Untersuchung von Boden und Kompost nach § 32 AbfKlärV 2017; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Fachmodule Wasser und Abfall |
this accreditation applies for the locations
Gräfenhäuser Straße 118, 64293 Darmstadt Söhnleinstraße 158, 65201 Wiesbaden Schwanheimer Ufer 167, 60529 Frankfurt am Main
sampling as well as physical, physico-chemical, chemical, microbiological and biological analysis of water; sampling as well as physical, physico-chemical and chemical analysis of sewage sludge and biowaste; selected physico-chemical analysis of soil and zinc metal; analysis according to decree about drinking water with except of the radioactive substances, sampling of raw- and drinking water; sampling and microbiological analysis of water from cooling plants; pretreatment and analysis of soil and compost according to § 32 AbfKlärV 2017; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; modul water and waste |
D-PL-19368-01-00 Scope
BGD ECOSAX GmbH Tiergartenstraße 48; 01219
Dresden
|
Sachsen
+49 351 47878 9810
+49 351 47878 9899
p.dost @ bgd-ecosax.de
|
A03, A09, A10, A100, A101, A102, A103, A105, A107, A109, A14, RN27, RN29, Anlage |
Probenahme von Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, von Abwasser, Böden, Sedimenten, Abfällen und Stoffen zur Verwertung; physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser (Abwasser, Grundwasser, Oberflächenwasser, wässrige Eluate), Schlamm, Sedimenten und Böden; ausgewählte biologische Untersuchungen von Wasser und Böden; Untersuchungen zur Ermittlung von Migrationsparametern für den Boden- Grundwasserbereich und zur Sickerwasserprognose; Fachmodule Wasser sowie Boden und Altlasten |
sampling of water from stagnant water, ground water, running water, of sewage, grounds, sediments, wastes and materials for reuse; physical, physico-chemical and chemical analysis of water (sewage, ground water, surface water, Aqueou eluate), mud, sediments and grounds; selected biological analysis of water and grounds; analysis for determination of migration parameters for den soil- ground water and for groundwater risk assessment; modul water as well as soil and old neglected deposits of toxic waste |
D-PL-21735-01-00 Scope
Thüringer Umweltinstitut Henterich GmbH Kielforstweg 2; 99819
Krauthausen
|
Thüringen
+49 36926 710090
+49 36926 710099
postmaster @ thuinst.de
|
A03, A28, B47, B51, RN24, RN27, RN28, Anlage |
physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser (Trinkwasser, Grundwasser, Oberflächenwasser, Sickerwasser, Brauchwasser, Abwasser, Schwimm- und Badebeckenwasser sowie wässrigen Eluaten), Schlamm, Boden, Sediment, Abfall und Stoffen zur Verwertung, Baustoff- und Baustoffgemischen; Probenahme von Wasser (Roh- und Trinkwasser, Grundwasser, Schwimm- und Badebeckenwasser sowie Abwasser), Schlamm, Klärschlamm, Abfall und Stoffen zur Verwertung; Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe; Fachmodule Wasser und Abfall |
physical, physical-chemical and chemical analysis of water (drinking water, ground water, surface water, deposite water, process water, sewage, swim- and bath water as well as aqueous eluat), mud, soil, sediment, waste and materials for reuse, building materials- and building material mixtures; sampling of water (raw- and drinking water, ground water, swim- and bath water as well as sewage), mud, sewage sludge, waste and materials for reuse; analysis according to decree about drinking water with except of the radioactive substances; modul water and waste |
D-PL-14148-01-00 Scope
SGL Spezial- und Bergbau-Servicegesellschaft Lauchhammer mbH Analytisches Labor
Vorberger Straße 8; 03222
Lübbenau
|
Brandenburg
+49 3542 88969910
+49 3542 88969929
s.thoma @ sgl-mbh.de
|
A03, A10, A100, A101, A102, A104, A106, A14, A28, B03, B37, B47, B51, RN24, RN25, RN27, RN28, RN29, RN36, Anlage |
Diese Akkreditierung gilt für die Standorte Vorberger Straße 8, 03222 Lübbenau/Spreewald Zweite Allee 1, 02929 Rothenburg/O.L.
physikalische, physikalisch-chemische, chemische und mikrobiologische Untersuchungen von Wasser (Abwasser, Grundwasser, Deponiesickerwasser, Badegewässern, technischen Wässern), Schlämmen, Sedimenten, Abfall, Stoffen zur Verwertung, Böden; ausgewählte Schnelltests zur Wasseranalytik mit Fertigreagenzien; Untersuchungen von Phyto- und Zooplankton; physikalische, physikalisch-chemische und chemische Untersuchungen von Bodenluft, Altölen und Mineralölen und festen Brennstoffen (inkl. Holz und deren Aschen); Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe, Probenahme von Roh- und Trinkwasser; Probenahme von Wasser, Abwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, von Kühlwasser für den industriellen Gebrauch, von Schlämmen, Sedimenten, Böden, Bodenluft, Abfall und Stoffen zur Verwertung; Fachmodule Wasser, Abfall sowie Boden und Altlasten |
this accreditation applies for the locations Vorberger Straße 8, 03222 Lübbenau/Spreewald Zweite Allee 1, 02929 Rothenburg/O.L.
physical, physical-chemical, chemical and microbiological analysis of water (sewage, ground water, seepage water of waste disposal sites, bathing water, tchnical water), sludges, sediments, waste, materials for reuse, grounds; selected fast tests for water analytics with finished reagents; analysis of phyto- and zooplankton; physical, physical-chemical and chemical analysis of soil gas, Altölen and oils and solid fuels (included. wood and whose ashes); analysis according to decree about drinking water with except of the radioactive substances, sampling of raw- and drinking water; sampling of water, sewage, water from stagnant water, ground water, running water, of cooling water for den industrial use, of sludges, sediments, grounds, soil gas, waste and materials for reuse; modul water, waste as well as soil and old neglected deposits of toxic waste |
D-PL-14628-01-00 Scope
GeoRisk Ingenieurgesellschaft für Altlasten- und Risikomanagement mit beschränkter Haftung Solitudeallee 14; 70439
Stuttgart
|
Baden-Württemberg
+49 711 83950530
+49 711 83950550
info @ georisk.de
|
A03, A10, A100, A101, A102, A103, A28, B47, B51, RN27, RN28, RN29, Anlage |
Probenahme von Grundwasser, von Böden, Abfällen, Stoffen zur Verwertung und Bodenluft; ausgewählte physikalisch-chemische Untersuchungen zur Wasserprobenahme; Fachmodule Wasser sowie Boden und Altlasten |
sampling of ground water, of grounds, wastes, materials for reuse and soil gas; selected physico-chemical analysis for water sampling; modul water as well as soil and old neglected deposits of toxic waste |
D-PL-14081-01-00 Scope
Eurofins Umwelt Ost GmbH Löbstedter Straße 78; 07749
Jena
|
Thüringen
+49 3731 207 6527
+49 3731 207 6555
de28_mbx_qmb @ eurofins.de
|
A03, A04, A21, A28, B37, B47, B51, B54, RN27, RN28, RN29, RN35, RN37, Anlage |
Diese Akkreditierung gilt für die folgenden Standorte:
Löbstedter Straße 78, 07749 Jena Niederlassung Freiberg Lindenstraße 11, 09627 Bobritzsch-Hilbersdorf Außenstelle Greiz Liebigstraße 7, 07973 Greiz-Dölau Niederlassung Oranienburg Lehnitzstraße 73, 16515 Oranienburg Rudower Chaussee 29, 12489 Berlin Edisonstraße 63, 12459 Berlin Max-Planck-Straße 4, 85609 Dornach bei München
physikalische, physikalisch-chemische, chemische, biologische und mikrobiologische Untersuchungen von Wasser (Grundwasser, Oberflächenwasser, Sickerwasser, Schwimm- und Badebeckenwasser, Badegewässer, Kleinbadeteiche, Kühlwässer, Prozess- und Brauchwasser, Abwasser und wässrige Eluate); physikalische, physikalisch-chemische, chemische, sensorische und biologische Untersuchungen von Böden, Sedimenten, Gesteinskörnungen, Abfall und Stoffen zur Verwertung oder Ablagerung; physikalische, physikalisch-chemische, chemische und ausgewählte biologische Untersuchungen von Klärschlamm und Schlämmen; physikalische, physikalisch-chemische, chemische und ausgewählte mikrobiologische Untersuchungen von Kompost, Bioabfall, Kultursubstraten, Bodenverbesserungsmitteln, Düngemitteln, Biomassen, Gärresten, Pflanzen; physikalische, physikalisch-chemische und chemische Untersuchungen von Holz, flüssigen, festen und gasförmigen Brennstoffen, Ölen, Bioethanol, Aschen, Bodenluft, Deponiegas und sonstigen Feststoffen (wie Kunststoffe, Baustoffe, keramische Werkstoffe, Papier, Streusalz, Kalk); mikrobiologische Untersuchungen des Oberflächenkeimgehaltes auf Einrichtungs- und Bedarfsgegenständen; Probenahme und mikrobiologische Untersuchungen zur Überprüfung von RLT-Anlagen; Probenahme von Abwasser, aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, von Schwimm- und Badebeckenwasser, Badegewässern, Schwebstoffen, Boden, Sedimenten, Abfall, Kompost, Gesteinskörnungen, Klärschlamm, Bodenluft, Bauschutt, Holz, Brennstoffen, Anzündhilfen, Grillkohle, Einweggrill, Altöl und Bioethanol; mikrobiologische und ausgewählte chemische Parameter gemäß Trinkwasserverordnung, Probenahme von Roh- und Trinkwasser; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Fachmodule Wasser, Boden und Altlasten sowie Abfall |
this accreditation applies for the following locations:
Löbstedter Straße 78, 07749 Jena branch Freiberg Lindenstraße 11, 09627 Bobritzsch-Hilbersdorf Branch office Greiz Liebigstraße 7, 07973 Greiz-Dölau branch Oranienburg Lehnitzstraße 73, 16515 Oranienburg Rudower Chaussee 29, 12489 Berlin Edisonstraße 63, 12459 Berlin Max-Planck-Straße 4, 85609 Dornach at München
physical, physico-chemical, chemical, biological and microbiological analysis of water (ground water, surface water, deposite water, swim- and bath water, Bathing waters, Small swimming ponds, Cooling water, process- and process water, sewage and Aqueou eluate); physical, physico-chemical, chemical, sensoric and biological analysis of grounds, sediments, stone granulate, waste and materials for reuse or deposite; physical, physico-chemical, chemical and selected biological analysis of sewage sludge and sludges; physical, physico-chemical, chemical and selected microbiological analysis of compost, biowaste, growing media, soil conditioners, fertilizers, biomasses, digestate, plant material; physical, physico-chemical and chemical analysis of wood, liquid, solid and gaseous fuels, oil, bioethanol, ashes, soil gas, dump gas and other solids (and plastic materials, construction materials, ceramic materials, paper, salt, CaCO3); microbiological analysis of Surface germ content at equipment- and demand articles; sampling and microbiological analysis for checkup of RLT-facilities; sampling of sewage, from stagnant water, ground water, running water, of swim- and bath water, bathing water, suspended particles, soil, sediments, waste, compost, stone granulate, sewage sludge, soil gas, building rubble, wood, fuels, Firelighters, Charcoal, Disposable grill, oil and bioethanol; microbiological and selected chemical parameter according to decree about drinking water, sampling of raw- and drinking water; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; modul water, soil and old neglected deposits of toxic waste as well as waste |
D-PL-14026-01-00 Scope
UCL Umwelt Control Labor GmbH
Josef-Rethmann-Straße 5; 44536
Lünen
|
Nordrhein-Westfalen
+49 2306 24090
+49 2306 240910
info @ ucl-labor.de
|
A01, A03, A101, A102, A105, A107, A109, A113, A21, A24, A28, B47, B51, RN01, RN24, RN25, RN27, RN28, RN29, RN30, RN35, RN36, RN37, Anlage |
Diese Akkreditierung gilt für die Standorte
Josef-Rethmann-Straße 5, 44536 Lünen Bienroder Weg 53, 38108 Braunschweig Köpenicker Straße 59, 24111 Kiel Schanzenstraße 10, 25746 Heide
physikalische, physikalisch-chemische, chemische, biologische und mikrobiologische Untersuchungen von Wasser (Grundwasser, Oberflächenwasser, Abwasser, Kühlwässern, Wasser aus Rückkühlwerken, Trinkwasser, Rohwasser), Schlämmen, Sedimenten, Böden, Klärschlamm, Abfall, Bioabfall, Stoffen zur Verwertung, Sekundärbrennstoffen, Biobrennstoffen, Recyclingprodukten, Mineralölen, Altholz, Altöl, Bodenluft und Deponiegasen; Probenahme von Abwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, Schwimm- und Badebeckenwasser, Mineral- und Heilquellen, Schlämmen, Sedimenten, Klärschlamm, Abfall, Bioabfall, Stoffen zur Verwertung, Sekundärbrennstoffen, Altholz, Altöl, Recyclingprodukten, landwirtschaftlichen Nutzböden, Kompost, Mineralölerzeugnissen, Bodenluft und Deponiegasen; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV 2017; chromatographische Bestimmung von Pestiziden in Wasser und Böden; Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe, Probenahme von Roh- und Trinkwasser; Probenahme, Probevorbereitung und Untersuchung von Abfällen nach Deponieverordnung Anhang 4; Probennahme, Probenvorbereitung und Untersuchung von Boden, Klärschlamm, Klärschlammgemisch und Klärschlammkompost nach §32 AbfKlärV 2017; Untersuchungen auf polyhalogenierte Dibenzo-p-Dioxine und Dibenzofurane und dioxin-ähnliche PCB in Wasser, Sedimenten, Klärschlamm, Stoffen zur Verwertung, Staub, Böden, Kompost, Mineralölen und Brandrückständen; Ermittlung von organischen gasförmigen Luftinhaltsstoffen, von faserförmigen Partikeln und von mikrobiologischen Inhaltsstoffen in Innenräumen; Ermittlung von Aerosolen und Faserstäuben, von anorganischen und organischen Gasen und Dämpfen sowie von ausgewählten Parametern bei Arbeitsplatzmessungen gemäß Gefahrstoffverordnung §7, Abs. 10; Probenahme und Analytik von Biogas, Brenngas, Deponiegas, Klärgas; Bestimmung von Emissionen aus Bauprodukten, Einrichtungsgegenständen, Bedarfsgegenständen mittels Prüfkammerverfahren; Reinräume und zugehörige Reinraumbereiche - Klassifizierung der Luftreinheit anhand der Partikelkonzentration; Fachmodule Wasser, Boden und Altlasten sowie Abfall; Modul Immissionsschutz; Ermittlung von anorganischen und organischen gas- oder partikelförmigen Luftinhaltsstoffen; spezielle Probenahme und Analyse von Stoffen, die einen besonderen Aufwand bei der Probenahme oder Analyse erfordern (luftgetragene polyhalogenierte Dibenzo-p-dioxine und Dibenzofurane und dioxin-ähnliche PCB); Ermittlung der Verbrennungsbedingungen; Kalibrierungen und Funktionsprüfungen kontinuierlich arbeitender Emissionsmesseinrichtungen für anorganische und organische gas- oder partikelförmige Luftinhaltsstoffe, sowie an Anlagen nach 4. BImSchV, Anhang Spalte 1; Ermittlung von anorganischen und organischen partikelförmigen Luftinhaltsstoffen und Bioaerosolen und Fasern bei Immissionen |
this accreditation applies for the locations
Josef-Rethmann-Straße 5, 44536 Lünen Bienroder Weg 53, 38108 Braunschweig Köpenicker Straße 59, 24111 Kiel Schanzenstraße 10, 25746 Heide
physical, physico-chemical, chemical, biological and microbiological analysis of water (ground water, surface water, sewage, cooling waters, water from cooling plants, drinking water, raw water), sludges, sediments, grounds, sewage sludge, waste, biowaste, materials for reuse, secondary fuels, biofuels, recycled products, oils, matured wood, oil, soil gas and disposal site gases; sampling of sewage, water from stagnant water, ground water, running water, swim- and bath water, mineral- and healing spring, sludges, sediments, sewage sludge, waste, biowaste, materials for reuse, secondary fuels, matured wood, oil, recycled products, agricultural existing floor coverings, compost, mineral oil products, soil gas and disposal site gases; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv 2017; chromatographic determination of pesticides in water and grounds; analysis according to decree about drinking water with except of the radioactive substances, sampling of raw- and drinking water; sampling, Sample preparation and analysis of wastes according to landfill regulation annex 4; sampling, pretreatment and analysis of soil, sewage sludge, Sewage sludge mixture and Sewage sludge compost according to §32 AbfKlärV 2017; analysis at polyhalogenied Dibenzo-P-dioxine and Dibenzofuranes and Dioxine-ähnliche PCB in water, sediments, sewage sludge, materials for reuse, dust, grounds, compost, oils and Fire arrears; determination of organic gaseous air constituents, of fibrous particle and of microbiological ingredients in indoors; determination of air and fibrous dusts, of inorganic and organic gas and steam as well as of selected parameters at workplace measurements according to German regulation of dangerous materials §7, Chapter. 10; sampling and analytics of biogas, Fuel gas, dump gas, Sewage gas; determination of emission from Building products, furniture, demand articles using Test chamber procedure; Clean rooms and associated Clean room areas - classification of the Air purity basis of the Particle concentration; modul water, soil and old neglected deposits of toxic waste as well as waste; modul Imission protection; determination of inorganic and organic gas- or particulate air constituents; special sampling and analysis of materials, the a special efforts at of the sampling or analysis require (air transported polyhalogenied Dibenzo-P-dioxine and Dibenzofuranes and Dioxine-ähnliche PCB); determination of the combustion conditions; calibrations and functional tests continual working emission measuring equipment for inorganic and organic gas- or particulate air pollutants, as well as at facilities according to 4. blmschv, annex column 1; determination of inorganic and organic particulate air constituents and bioaerosols and fibres at immissions |
D-PL-14263-01-00 Scope
CHEMAD GmbH Buschstraße 95; 47166
Duisburg
|
Nordrhein-Westfalen
|
A03, A10, A24, A28, B37, B47, B51, RN27, RN28, RN29, Anlage |
physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser, Abwasser, Schlamm, Sedimenten, Abfällen und Stoffen zur Verwertung; ausgewählte Untersuchungen an Mineralölen, Brennstoffen, Koks und Kohle; chemische Untersuchungen von Zinksulfaten und zinkhaltigen Rohstoffen; physikalische und chemische Untersuchungen von Erzen, Gießereirohstoffen, Metallprodukten, Ferrolegierungen, Galvanik- und Verzinkungsbädern, Abwasser und Schwefelsäure; Probenahme von Wasser, Abwasser, Schlämmen und Abfällen; Fachmodule Wasser, Boden und Altlasten sowie Abfall |
physical, physico-chemical and chemical analysis of water, sewage, mud, sediments, wastes and materials for reuse; selected analysis at oils, fuels, coke and coal; chemical analysis of zinc sulfate and zinc raw material; physical and chemical analysis of oars, foundry raw materials, metal products, iron alloys, electroplating- and galvanizing, sewage and sulfuric acid; sampling of water, sewage, sludges and wastes; modul water, soil and old neglected deposits of toxic waste as well as waste |
D-PL-14114-01-00 Scope
Aggerverband Labor
Sonnenstraße 40; 51645
Gummersbach
|
Nordrhein-Westfalen
+49 2261 361401
+49 2261 3681401
labor @ aggerverband.de
|
A03, A04, A28, B51, RN24, RN25, RN27, RN35, Anlage |
mikrobiologische, sensorische, physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser (Trinkwasser, Rohwasser, Prozesswasser, Wasser aus leitungsgebundenen und nicht leitungsgebundenen Wasserspendern, Wasser aus Wasserzählern, Grundwasser, Oberflächenwasser, Schwimm- und Badebeckenwasser, Abwasser); Probenahme von Schwimm- und Badebeckenwasser, Abwasser, aus Fließgewässern und stehenden Gewässern, aus (leitungsgebundenen und nicht leitungsgebundenen) Wasserspendern und aus Wasserzählern, von Wasser aus Aufbereitungsanlagen zur Trinkwassergewinnung; mikrobiologische und ausgewählte chemische Untersuchungen gemäß Trinkwasserverordnung; Probenahme von Roh- und Trinkwasser; Fachmodul Wasser |
microbiological, sensoric, physical, physico-chemical and chemical analysis of water (drinking water, raw water, process water, water from wired and non wired water dispensers, water from Wasserzählern, ground water, surface water, swim- and bath water, sewage); sampling of swim- and bath water, sewage, from running water and stagnant water, from (wired and non wired) water dispensers and from Wasserzählern, of water from treatment plants for drinking water production; microbiological and selected chemical analysis according to drinking water regulations; sampling of raw- and drinking water; expert modul water |
D-PL-17298-01-00 Scope
IUQ Institut für Umweltschutz und Qualitätssicherung Dr. Krengel GmbH
Grüner Weg 16a; 23936
Grevesmühlen
|
Mecklenburg-Vorpommern
+49 3881 78390
+49 3881 783941
info @ iuq.de
|
A03, A100, A101, A102, A14, A28, B37, B47, B51, B53, B54, RN24, RN25, RN27, RN28, Anlage |
physikalische, physikalisch-chemische, chemische und mikrobiologische Untersuchungen von Wasser (Grundwasser, Schwimm- und Badebeckenwasser, Sickerwasser, Oberflächenwasser und Abwasser), Schlamm, marinen und limnischen Sedimenten, Böden, Abfall und Klärschlamm, Stoffen zur Verwertung, Kompost, Brennstoffen, Holz, Holzpellets, Bioabfall, Deponiegasen und Bodenluft; Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe, Probennahme von Roh- und Trinkwasser; Probenahme von Abwasser, Kühlwasser, Schwimm- und Badebeckenwasser, Oberflächenwasser, aus Grundwasserleitern, Fließgewässern, von Schlämmen, marinen und limnischen Sedimenten, Böden, Kompost, Abfall, Brennstoffen, Holz, Holzpellets sowie von Deponiegasen; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Fachmodule Abfall und Wasser |
physical, physico-chemical, chemical and microbiological analysis of water (ground water, swim- and bath water, deposite water, surface water and sewage), mud, marine and limnetic sediments, grounds, waste and sewage sludge, materials for reuse, compost, fuels, wood, wood pellets, biowaste, disposal site gases and soil gas; analysis according to decree about drinking water with except of the radioactive substances, sampling of raw- and drinking water; sampling of sewage, cooling water, swim- and bath water, surface water, from ground water, running water, of sludges, marine and limnetic sediments, grounds, compost, waste, fuels, wood, wood pellets as well as of disposal site gases; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; modul waste and water |
D-PL-14333-01-00 Scope
Industrie- und Umweltlaboratorium Vorpommern GmbH Am Koppelberg 20; 17489
Greifswald
|
Mecklenburg-Vorpommern
+49 3834 574513
+49 3834 574515
mail @ iul-vorpommern.de
|
A03, A04, A101, A105, A107, A109, A21, A28, A29, B03, B37, B47, B51, B54, RN24, RN27, RN28, RN29, RN35, RN36, RN37, Anlage |
physikalische, physikalisch-chemische, chemische und biologische Untersuchungen von Grundwasser, Oberflächenwasser, Schwimm- und Badebeckenwasser, Meerwasser, Abwasser sowie Prozesswässern; physikalische, physikalisch-chemische, chemische Untersuchungen von Schlamm, Klärschlamm, Bioabfall, Sedimenten, Abfall, Stoffen zur Verwertung, Holz, Boden, Baustoffen- und Baustoffgemischen sowie Sekundärbrennstoffen; ausgewählte chemische Untersuchungen gemäß Trinkwasserverordnung, Probenahme von Roh- und Trinkwasser; Probenahme für mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Ermittlung (Probenahme und Analytik) gasförmiger organischer Luftinhaltsstoffe in Innenraumluft, Prüfkammeruntersuchungen; ausgewählte Untersuchungen von Mineralölerzeugnissen und Isolieröl; Probenahme von Abwasser, aus stehenden Gewässern, Grundwasserleitern, Fließgewässern sowie von Schwimm- und Badebeckenwasser, Schlamm, Klärschlamm, Bioabfall, Sedimenten, Abfall und Deponiegas; Fachmodule Wasser, Boden und Altlasten sowie Abfall |
physical, physico-chemical, chemical and biological analysis of ground water, surface water, swim- and bath water, sea water, sewage as well as process water; physical, physico-chemical, chemical analysis of mud, sewage sludge, biowaste, sediments, waste, materials for reuse, wood, soil, building materials- and building material mixtures as well as secondary fuels; selected chemical analysis according to decree about drinking water, sampling of raw- and drinking water; sampling for microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; determination (sampling and analytics) gas organic air pollutants in indoor air, test chamber; selected analysis of mineral oil products and iosolation oil; sampling of sewage, from stagnant water, ground water, running water as well as of swim- and bath water, mud, sewage sludge, biowaste, sediments, waste and dump gas; modul water, soil and old neglected deposits of toxic waste as well as waste |
D-PL-20754-01-00 Scope
BLS-Analytik GmbH Columbiastraße 14; 97688
Bad Kissingen
|
Bayern
|
B14, B51, RN27, Anlage |
Bestimmung von Vitaminen (Vitamin B1, Vitamin B2, Vitamin B6, Vitamin K) in Lebensmitteln mittels Hochdruckflüssigkeitschromatographie; Probenvorbereitung zur Untersuchung von Metallen und Schwermetallen mittels Druckaufschluss; Bestimmung von Metallen und Schwermetallen in Lebensmitteln mittels Atomabsorptionsspektrometrie |
determination of vitamins (vitamin b1, vitamin b2, vitamin b6, vitamin K) in food using HPLC; pretreatment for analysis of metals and heavy metals using pressure digestion; determination of metals and heavy metals in food using AAS |
D-PL-19357-01-00 Scope
UWAT - Ingenieurbüro und Labor für Umweltfragen GmbH Hofeweg 12 a; 02730
Ebersbach/Sa.
|
Sachsen
+49 3586 30240
+49 3586 302419
info @ uwat.de
|
A03, A28, A29, B02, B51, RN27, Anlage |
physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser (Brauchwasser, Rohwasser, Grundwasser, Oberflächenwasser, Abwasser); Probenahme von Abwasser; Fachmodul Wasser |
physical, physico-chemical and chemical analysis of water (process water, raw water, ground water, surface water, sewage); sampling of sewage; expert modul water |
D-PL-14115-02-17 Scope
SGS INSTITUT FRESENIUS GmbH Im Maisel 14; 65232
Taunusstein
|
Hessen
+49 6128 744 459
+49 6128 744 9902
tobias.holke @ sgs.com
|
A03, A04, A10, A100, A101, A21, A24, A26, A28, A30, B02, B03, B06, B09, B10, B14, B24, B30, B36, B37, B41, B47, B49, B51, B53, B54, RN24, RN25, RN27, RN28, RN35, Anlage |
Arzneimittel und Wirkstoffe
Prüfgebiet: Wirksamkeitsprüfung von Desinfektionsmittel |
drugs and active ingredients
field of tests: Efficiency tests of desinfectants |
D-PL-14115-02-14 Scope
SGS INSTITUT FRESENIUS GmbH Güttinger Straße 37; 78315
Radolfzell
|
Baden-Württemberg
+49 6128 744 459
+49 6128 744 9902
tobias.holke @ sgs.com
|
A03, A04, A10, A100, A101, A21, A24, A26, A28, A30, B02, B03, B06, B09, B10, B14, B24, B30, B36, B37, B41, B47, B49, B51, B53, B54, RN24, RN25, RN27, RN28, RN35, Anlage |
ausgewählte physikalische, physikalisch-chemische, chemische Untersuchungen von Wasser, Abwasser, Oberflächenwasser, Grundwasser, Mineralwasser, Heilwasser, Badebeckenwasser, Trinkwasser, Wasser aus Rückkühlwerken und Raumlufttechnischen Anlagen; mikrobiologische Untersuchungen von Wasser, Abwasser, Grundwasser, Mineralwasser, Heilwasser, Kühlwasser, Wasser zur Herstellung von Lebensmitteln und Kosmetika und von Bioabfall; ausgewählte chemische und mikrobiologische Untersuchungen gemäß Trinkwasserverordnung; ausgewählte mikrobiologische Verfahren zur Untersuchung von Lebensmitteln und Luft; Probenahme von Abwasser, Roh- und Trinkwasser, Heil- und Mineralwasser, Schwimm- und Badebeckenwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, Wasser aus Rückkühlwerken und Raumlufttechnischen Anlagen, von Abfall, Schlamm, Sedimenten, Altholz, Altöl, Abfall zur Ablagerung und landwirtschaftlichen Böden; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Fachmodule Wasser und Abfall |
selected physical, physico-chemical, chemical analysis of water, sewage, surface water, ground water, mineral water, medicinal water, bath water, drinking water, water from cooling plants and hvac facilities; microbiological analysis of water, sewage, ground water, mineral water, medicinal water, cooling water, water for manufacture of food and cosmetics and of biowaste; selected chemical and microbiological analysis according to decree about drinking water; selected microbiological procedure for analysis of food and air; sampling of sewage, raw- and drinking water, health- and mineral water, swim- and bath water, water from stagnant water, ground water, running water, water from cooling plants and hvac facilities, of waste, mud, sediments, matured wood, oil, waste for deposite and agricultural grounds; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; modul water and waste |
D-PL-14115-02-00 Scope
SGS INSTITUT FRESENIUS GmbH Im Maisel 14; 65232
Taunusstein
|
Hessen
+49 6128 744 459
+49 6128 744 9902
tobias.holke @ sgs.com
|
A03, A04, A10, A100, A101, A21, A24, A26, A28, A30, B02, B03, B06, B09, B10, B14, B24, B30, B36, B37, B41, B47, B49, B51, B53, B54, RN24, RN25, RN27, RN28, RN35, Anlage, Annex |
physikalische, physikalisch-chemische, chemische, mikrobiologische, ökotoxikologische, biologische, biochemische und organoleptische Untersuchungen von Lebensmitteln, Wasser, Heil- und Mineralwasser, Badewasser, Brauchwasser, Abwasser, von Abfall, Stoffen zur Verwertung, Böden, Staub, Asche und Schlacke; Untersuchungen von elektrotechnischen Produkten; Untersuchungen organisch-chemischer Produkte; chemische Untersuchungen von Metallen, Stählen und Legierungen; chemische, physikalische, mikrobiologische und mechanisch-technologische Untersuchungen von Textilien und Leder; Ermittlung von Aerosolen, anorganischen und organischen Gasen und Dämpfen sowie ausgewählten Parametern bei Arbeitsplatzmessungen gemäß Gefahrstoffverordnung §7, Abs. 10; Bestimmung von luftgetragenen Schadstoffen sowie Keimen und Schimmel in der Luft in Innenräumen; Untersuchungen gemäß Trinkwasserverordnung mit Ausnahme der radioaktiven Stoffe; Probenahme und mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Probenahme von Roh- und Trinkwasser, Wasser aus Mineral- und Heilquellen, Grundwasserleitern, stehenden Gewässern, von Schwimm- und Badebeckenwasser, Abwasser, aus fließenden Gewässern, von Deponiesickerwasser, Wasser aus Rückkühlwerken, technisch aufbereitetem Wasser, Lebensmitteln, Pflanzenmaterialien, landwirtschaftlich genutzten Böden, Sedimenten, Klärschlamm, Bioabfall, Abfall und Staub, Stoffen zur Verwertung; Fachmodule Wasser und Abfall |
physical, physico-chemical, chemical, microbiological, ecotoxicological, biological, biochemical and organoleptic analysis of food, water, health- and mineral water, bath water, process water, sewage, of waste, materials for reuse, grounds, dust, ashes and cinder; analysis of electrotechnical products; analysis orcanic-chemical products; chemical analysis of metals, steels and alloys; chemical, physical, microbiological and mechanically-technological analysis of textiles and leather; determination of air, inorganic and organic gas and steam as well as selected parameters at workplace measurements according to German regulation of dangerous materials §7, Chapter. 10; determination of airborne pollutants as well as germinate and mold in of the air in indoors; analysis according to decree about drinking water with except of the radioactive substances; sampling and microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; sampling of raw- and drinking water, water from mineral- and healing spring, ground water, stagnant water, of swim- and bath water, sewage, from flowing water, of seepage water of waste disposal sites, water from cooling plants, technically treated water, food, plant materials, agricultural used grounds, sediments, sewage sludge, biowaste, waste and dust, materials for reuse; modul water and waste |
D-PL-14115-02-07 Scope
SGS INSTITUT FRESENIUS GmbH Am Technologiepark 10; 45699
Herten
|
Nordrhein-Westfalen
+49 6128 744 459
+49 6128 744 9902
tobias.holke @ sgs.com
|
A03, A04, A10, A100, A101, A21, A24, A26, A28, A30, B02, B03, B06, B09, B10, B14, B24, B30, B36, B37, B41, B47, B49, B51, B53, B54, RN24, RN25, RN27, RN28, RN35, Anlage |
Diese Akkreditierung gilt für die Standorte:
Am Technologiepark 10, 45699 Herten Rödingsmarkt 16, 20459 Hamburg
physikalische, physikalisch-chemische und chemische Untersuchungen von Wasser, Abwasser, Grundwasser, Schlamm, Sedimenten, Abfall, Stoffen zur Verwertung, Boden und Bodenluft; chemische und sensorische Untersuchungen gemäß Trinkwasserverordnung; Probenahme von Abwasser, Roh- und Trinkwasser, Wasser aus stehenden Gewässern, Grundwasserleitern, Fließgewässern, Schlämmen, Sedimenten, Abfall, festen Sekundärbrennstoffen und Bodenluft; Probenahme für mikrobiologische Untersuchungen von Nutzwasser gemäß §3 Absatz 8 42. BImSchV; Untersuchung von Abfall zur Ablagerung nach Deponieverordnung Anhang 4; ausgewählte Probenahmen und Untersuchungen von Innenraum- und Außenluft; Fachmodule Wasser, Boden und Altlasten sowie Abfall |
this accreditation applies for the locations:
am Technologiepark 10, 45699 Herten Rödingsmarkt 16, 20459 Hamburg
physical, physico-chemical and chemical analysis of water, sewage, ground water, mud, sediments, waste, materials for reuse, soil and soil gas; chemical and sensoric analysis according to decree about drinking water; sampling of sewage, raw- and drinking water, water from stagnant water, ground water, running water, sludges, sediments, waste, solid secondary fuels and soil gas; sampling for microbiological analysis of industrial water according to §3 distribution 8 42. blmschv; analysis of waste for deposite according to landfill regulation annex 4; selected sampling and analysis of interior- and exterior; modul water, soil and old neglected deposits of toxic waste as well as waste |
Search to
Search text - Field number = 'RN27' Type of Accreditation='ALL' Location='ALL' Field Calibration='ALL' Field Testing (Tests)='ALL' Field Testing, Certification for Products (Products, Objects)='ALL' Field Certification for Persons='ALL' Field Certification for Managementsystem (Objects)='ALL' Field Certification for Managementsystem 2='ALL' Field Certification for the categories requested LSMS='ALL' Field European legislation='ALL' Field National legislation='ALL' Field Scopes of accreditation='ALLE' Additional output from Scope ? German and English
Case sensitivity? No
|
|