D-ZE-12007-01-12 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Annex |
Cyber Security according to the certification scheme for compliant objects, components, devices, systems and applications including the management of secure product / system development, applications and operation according to sectors listed in this attachment, mainly: - Power plant control and safety technology, including nuclear applications Process technology, control systems - Manufacturing technology - Rail technology - Building and Infrastructure technology - Renewable technology - Machine and plant safety - - Automotive applications - Elevator systems, escalators and moving walkways - Industrial communication networks |
D-ZE-12007-01-10 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Anlage |
Zertifizierung von Türen (System zur Bewertung und Überprüfung der Leistungsbeständigkeit 1) im Rahmen der Verordnung (EU) Nr. 305/2011 zur Festlegung harmonisierter Bedingungen für die Vermarktung von Bauprodukten (Bauproduktenverordnung) |
D-ZE-12007-01-05 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Anlage |
Maschinen und Sicherheitsbauteile gemäß Richtlinie 2006/42/EG
Die Zertifizierungsstelle erfüllt die besonderen Anforderungen der Richtlinie 2006/42/EG an notifizierte Stellen |
Machines and safety components in accordance with Directive 2006/42 / EC
The certification body meets the special requirements of Directive 2006/42 / EC to notified bodies |
D-ZE-12007-01-06 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Annex |
Functional safety according to the following certification schemes for compliant objects, components, devices, systems and applications including functional safety management of: • Machines • Elevator systems, escalators and moving walkways • Automotive applications • Power plant control • Process technology , control systems |
D-ZE-12007-01-07 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Anlage |
Spielzeug gemäß Richtlinie 2009/48/EG sowie Konformitätsbewertungen gemäß §20 Produktsicherheitsgesetz (Zuerkennung des GS-Zeichens)
Die Zertifizierungsstelle erfüllt die besonderen Anforderungen der Richtlinie 2009/48/EG an notifizierte Stellen 1 und des § 23 Abs. 2 des Produktsicherheitsgesetzes an GS-Stellen |
Toys in accordance with Directive 2009/48 / EC and conformity assessments in accordance with §20 Product Safety Act (award of the GS mark)
The certification body fulfills the special requirements of Directive 2009/48 / EC for notified bodies 1 and § 23 (2) of the Product Safety Act at GS bodies |
D-ZE-12007-01-04 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Anlage |
Geräte und Schutzsysteme zur bestimmungsgemäßen Verwendung in explosionsgefährdeten Bereichen gemäß Richtlinie 2014/34/EU
Die Zertifizierungsstelle erfüllt die besonderen Anforderungen der Richtlinie 2014/34/EU an notifizierte Stellen |
Equipment and protective systems intended for use in potentially explosive atmospheres in accordance with Directive 2014/34 / EU
The certification body meets the specific requirements of Directive 2014/34 / EU to notified bodies |
D-ZE-12007-01-09 Scope
TÜV NORD CERT GmbH Langemarckstraße 20; 45141
Essen
|
Nordrhein-Westfalen
|
B02, B09, B12, B14, B15, B25, B26, B27, B29, B40, B54, B58, B59, B63, B70, B71, REU02, REU08, REU12, REU19, REU24, REU64, RN21, Anlage |
Zertifizierungsprogramm der ARGE DIN 14675 vom 05.10.2017: Fachfirmen für Brandmeldeanlagen (BMA) nach DIN 14675:2012 sowie Fachfirmen für Sprachalarmanlagen (SAA) nach DIN 14675:2012 |
Certification program of ARGE DIN 14675 from 05.10.2017: Specialist companies for fire alarm systems (BMA) according to DIN 14675: 2012 as well as Specialist companies for voice alarm systems (SAA) according to DIN 14675: 2012 |
D-PL-17580-01-00 Scope
anemos Gesellschaft für Umweltmeteorologie mbH Böhmsholzer Weg 3; 21391
Reppenstedt
|
Niedersachsen
+49 4131 83080
+49 4131 8308199
kontakt @ anemos.de
|
A05, A09, A10, B71, Anlage, Annex |
Bestimmung von Windpotenzial und Energieerträgen von Windenergieanlage (WEA)-Standorte; Berechnung des zu erwartenden mittleren Jahresenergieertrages; Bestimmung der Standortgüte zur Inbetriebnahme; Durchführung, Auswertung und Analyse von Windmessungen mittels Anemometer, SoDAR und LiDAR; Berechnung der Turbulenzintensität; Schattenwurfberechnung von Windenergieanlagen; Schallimmissionsprognosen von Windenergieanlagen; Erstellung von Windatlanten sowie Bestimmung der Wind- und Ertragsindizes; Erstellung von Erlösgutachten; Berechnung von Marktwertatlanten |
Determination of the wind potential and energy yield of wind turbine sites; Calculation of the expected mean annual energy yield; Determination of the site quality at commissioning; Performance, evaluation and analysis of wind measurements with anemometers, SoDAR and LiDAR remote sensing devices; Calculation of the turbulence intensity; Calculation of the shadow impact of wind turbines; Prediction of the sound immission of wind turbines; Compilation of wind atlases and determination of the wind and energy yield indices; Preparation of revenue reports; Calculation of market value atlases |
D-PL-11233-01-00 Scope
WINDTEST Grevenbroich GmbH
Frimmersdorfer Straße 73a; 41517
Grevenbroich
|
Nordrhein-Westfalen
+49 2181 22780
+49 2181 227811
florian.schmidt @ windtest-nrw.de
|
A01, A07, A10, A29, B12, B28, B54, B71, Anlage |
Leistungsmessungen an Windenergieanlagen (Leistungskurve) sowie Verifizierung und Klassifizierung von Remote Sensing Devices (RSD); Windpotenzialmessungen und -berechnungen sowie Bestimmung des Energieertrages; Bestimmung der Standortgüte; Messungen und Berechnungen der elektrischen Eigenschaften von dezentralen Energieerzeugungseinheiten (EZE) in Verbindung mit dem elektrischen Versorgungsnetz (Elektromagnetische Verträglichkeit EMV) sowie Messung der Netzanschlussgrößen (Kraftwerksverhalten) von EZE und Energieerzeugungsanlagen (EZA); Beanspruchungsmessungen an Windenergieanlagen; Referenzertragsberechnungen; Schattenwurfermittlung; Modul Immissionsschutz: Ermittlung von Geräuschen; weitere Verfahren zur Bestimmung von Geräuschen |
Power measurements on wind turbines (performance curve) as well as verification and classification of Remote Sensing Devices (RSD); Wind potential measurements and calculations as well as determination of the energy yield; Determination of site quality; Measurements and calculations of the electrical properties of decentralized power generation units (EZE) in connection with the electrical supply network (electromagnetic compatibility EMC) as well as measurement of grid connection sizes (power plant behavior) of EZE and power generation plants (EZA); Load measurements on wind turbines; Reference yield calculations; Shadow detection; Module immission control: detection of noise; other methods for the determination of noise |
D-PL-14169-03-02 Scope
TÜV Rheinland LGA Products GmbH Tillystraße 2; 90431
Nürnberg
|
Bayern
+49 221 8062040
+49 221 8063935
heiner.luedemann @ de.tuv.com
|
A01, A03, A07, A08, A09, A16, A25, A28, A43, A45, A46, A48, B06, B09, B12, B15, B18, B26, B34, B51, B53, B69, B71, REU02, REU03, REU04, REU05, REU07, REU12, REU19, REU64, Anlage, Annex |
Prüfung der technischen Unterlagen und Ermittlung des Luftschalls von in dieser Anlage aufgeführten Geräten und Maschinen, Messung des Luftschalls zur Ermittlung des Schallleistungspegels für Geräte und Maschinen, Maschinenakustik, Maschinen, Bauakustik Prüfung von Bauprodukten im Rahmen der Verordnung (EU) Nr. 305/2011 zur Festlegung harmonisierter Bedingungen für die Vermarktung von Bauprodukten (Bauproduktenverordnung) Prüfung der Geräuschabsorption von Bauprodukten, für die die Angabe der Fundstelle einer einschlägigen harmonisierten technischen Spezifikation nicht erforderlich ist (Punkt 3. Anhang V, (EU) Nr. 305/2011) |
Examination of technical documentation and determination of the airborne noise of equipment and machinery listed in this appendix, measurement of airborne noise for determination of the sound power level of equipment, machine acoustics, machinery, building acoustics Testing of construction products under Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (Construction Products Regulation) Testing of noise absorption of construction products, where reference to a relevant harmonised technical specification is not required (point 3. Annex V, (EU) No. 305/2011) |
D-PL-14169-03-04 Scope
TÜV Rheinland LGA Products GmbH Tillystraße 2; 90431
Nürnberg
|
Bayern
+49 221 8062040
+49 221 8063935
heiner.luedemann @ de.tuv.com
|
A01, A03, A07, A08, A09, A16, A25, A28, A43, A45, A46, A48, B06, B09, B12, B15, B18, B26, B34, B51, B53, B69, B71, REU02, REU03, REU04, REU05, REU07, REU12, REU19, REU64, Anlage, Annex |
Biologische Prüfungen von Medizinprodukten sowie Sicherheitsprüfungen und Prüfungen der Verträglichkeit bezüglich elektromagnetischer Störgrößen (EMV) von aktiven Medizinprodukten und IVD-Geräten |
Biological testing of medical devices as well as safety tests and compatibility tests with regard to electromagnetic disturbances (EMC) of active medical devices and IVD devices |
D-PL-11315-01-00 Scope
Ingenieurbüro Dr.-Ing. Dieter Frey Bürgermeister-Kröger-Straße 17; 21244
Buchholz-Sprötze
|
Niedersachsen
+49 4186 5551
+49 4186 5044
dieter.frey @ ing-buero-frey.de
|
A07, B12, B27, B71, Anlage |
Messung der Leistungskennlinie an Windenergieanlagen; Belastungs- und Erprobungsmessungen an Windenergieanlagen; Strukturprüfungen an Rotorblättern, Windmessungen als Beitrag zu Bestimmung von Windpotenzial und Energieertrag von Windenergieanlagen; Standortgutachten - Bestimmung von Windpotential und Energieertrag von Windenergieanlagen |
measurement of the power curve at wind turbines; stress- and test measurements at wind turbines; structural Assessment at rotor blades, wind measurements as contribution for determination of wind potential and energy yield of wind turbines; site survey - determination of wind potential and energy yield of wind turbines |
D-ZE-12061-01-01 Scope
VDE Prüf- und Zertifizierungsinstitut GmbH Merianstraße 28; 63069
Offenbach am Main
|
Hessen
+49 69 8306377
+49 69 8306555
sofie.hagen @ vde.com
|
A07, A16, A43, B12, B26, B56, B58, B60, B69, B70, B71, REU12, REU19, REU64, REU69, Anlage, Annex |
D-ZE-12061-01-02 Scope
VDE Prüf- und Zertifizierungsinstitut GmbH Merianstraße 28; 63069
Offenbach am Main
|
Hessen
+49 69 8306377
+49 69 8306555
sofie.hagen @ vde.com
|
A07, A16, A43, B12, B26, B56, B58, B60, B69, B70, B71, REU12, REU19, REU64, REU69, Anlage, Annex |
D-IS-20739-01-00 Scope
Ackermann & Knorr Ingenieur GmbH Am Harthauer Bahnhof 11; 09125
Chemnitz
|
GERMANY
+49 371 853174
info @ ackermann-knorr.de
|
A17, A48, B71, Anlage |
Inspektionen von Windenergieanlagen und unmittelbar zum Betrieb notwendiger Nebeneinrichtungen sowie Ursachenermittlung durch Beurteilung und Feststellung der Übereinstimmung mit bestimmten und - aufgrund einer sachverständigen Beurteilung - mit allgemeinen Anforderungen |
inspections of wind turbines and immediately for operation necessary ancillary facilities as well as cause investigation by assessment and finding of the agreement with determination and - due to a expert assessment - with general requirements |
D-IS-20525-01-00 Scope
IfE Ingenieurgesellschaft für Energieprojekte mbH & Co. KG Ringstraße 2; 26721
Emden
|
GERMANY
+49 4921 97850
+49 4921 978519
info @ ife-emden.de
|
A48, B71, Anlage |
Technische Inspektion und Bewertung von Windenergieanlagen durch Beurteilung und Feststellung der Übereinstimmung mit bestimmten und aufgrund einer sachverständigen Beurteilung - mit allgemeinen Anforderungen |
technic inspection and rating of wind turbines by assessment and finding of the agreement with determination and due to a expert assessment - with general requirements |
D-IS-20523-01-00 Scope
OTR - Offshore Turbine Reports GmbH Ringstraße 2; 26721
Emden
|
GERMANY
+49 4921 978516
+49 4921 978519
info @ otr-germany.de
|
A48, B71, Anlage |
Technische Inspektion und Bewertung von Windenergieanlagen durch Beurteilung und Feststellung der Übereinstimmung mit bestimmten und aufgrund einer sachverständigen Beurteilung - mit allgemeinen Anforderungen |
technic inspection and rating of wind turbines by assessment and finding of the agreement with determination and due to a expert assessment - with general requirements |
D-ZE-19400-01-00 Scope
Hanseatic Power Cert GmbH Brandstwiete 4; 20457
Hamburg
|
GERMANY
+49 40 226 39 05 0
+49 40 226 39 05 99
office @ hpcert.com
|
B71, Anlage |
Projektzertifizierung von Offshorestrukturen und –anlagen: Windenergieanlagen, Umspann-, Umformer- und Wohnplattformen, Seekabel, meteorologische Masten |
project certification of offshore structures and equipment: wind turbines, Transformer-, converter- and residential platforms, submarine cable, meteorological masts |
D-PL-11132-01-00 Scope
GEO-NET Umweltconsulting GmbH
Große Pfahlstraße 5a; 30161
Hannover
|
Niedersachsen
+49 511 388 7220
+49 511 388 7201
info @ geo-net.de
|
A05, A09, B71, Anlage |
Durchführung, Auswertung und Analyse von Windmessungen mittels Messmast, LiDAR- und SoDAR-Messgeräten; Bestimmung von Windpotenzial und Energieerträgen von Windenergieanlagen; Bestimmung der Standortgüte; Bestimmung des Referenzertrages von Windenergieanlagen; Windfeldsimulation mit Mesoskalenmodellen; Führung des Nachweises der Standorteignung (Turbulenzgutachten) |
run, evaluation and analysis of wind measurements using mast, lidar- and sodar-Measuring instruments; determination of wind potential and energy yields of wind turbines; determination of the Standortgüte; determination of reference yield of wind turbines; wind field simulation with mesoskalenmodellen; guide of proof of the Standorteignung (turbulence Analysis) |
D-PL-11011-01-00 Scope
IEL GmbH
Kirchdorfer Straße 26; 26603
Aurich
|
Niedersachsen
+49 4941 95580
+49 4941 955811
mail @ iel-gmbh.de
|
A05, A09, A10, B44, B71, Anlage |
Bestimmung von Windpotenzial und Energieerträgen von Windenergieanlagen einschließlich Prüfung windklimatologischer Eingangsdaten; Bestimmung der Standortgüte zur Inbetriebnahme; Rotorschattenwurfberechnung von Windenergieanlagen; Ermittlung der Emissionen und Immissionen von Geräuschen in der Nachbarschaft; Modul Immissionsschutz- Gruppe V: Ermittlung von Geräuschen |
determination of wind potential and energy yields of wind turbines including testing climatological wind input data; determination of the Standortgüte for commissioning; Red shadow cast calculation of wind turbines; determination of the emission and immissions of noise in of the neighbourhood; modul Imission protection- group a.: determination of noise |
D-PL-11098-01-00 Scope
WIND - consult Ingenieurgesellschaft für umweltschonende Energiewandlung mbH Reuterstraße 9; 18211
Admannshagen-Bargeshagen
|
Mecklenburg-Vorpommern
+49 38203 50725
+49 38203 50723
company @ wind-consult.de
|
A01, A05, A09, A25, A26, A29, A30, B03, B09, B11, B54, B71, Anlage, Annex |
Messung des Leistungsverhaltens von Windenergieanlagen (WEA); Durchführung und Auswertung von Windmessungen mittels Anemometer und Fernmessverfahren; Messung der elektrischen Eigenschaften von Erzeugungseinheiten und -anlagen; Bestimmung von Windpotenzial und Energieerträgen sowie die Bestimmung der Standortgüte zur Inbetriebnahme gemäß Erneuerbare-Energien-Gesetz (EEG 2017); Bestimmung der Schall-Emission von WEA; Geräusche in der Nachbarschaft von WEA; Ermittlung des Schattenwurfs von WEA auf Flächen; Messung der Beanspruchung von WEA; Messungen zum Anlagenverhalten von WEA; Prüfung der Standorteignung; Ermittlung von Geräuschen (Gruppe V); Modul Immissionsschutz |
measurement of power performance of wind turbines (WEA); run and evaluation of wind measurements using anemometer and Fernmessverfahren; measurement of the electric properties of generating units and -facilities; determination of wind potential and energy yields as well as the determination of the Standortgüte for commissioning according to renewable-energy-law (EEG 2017); determination of the sound-emission of WEA; sound in of the neighbourhood of WEA; determination of shadows of WEA at surfaces; measurement of the stress of WEA; mesurement for investment behavior of WEA; testing of the Standorteignung; determination of noise (group a.); modul Imission protection |
D-ZE-14153-01-03 Scope
TÜV SÜD Industrie Service GmbH Zertifizierungsstelle für Fliegende Bauten, Windenergieanlagen, Klima und Energie Westendstraße 199; 80686
München
|
Bayern
+49 89 571 1090
+49 89 5791 2355
volker.rother @ tuev-sued.de
|
A07, B07, B25, B27, B29, B40, B42, B70, B71, M25, Anlage |
Beglaubigung von Anlage‐ und Produktionsdaten über den Nachweis der Energieträger und der Herkunft von Elektrizität gemäß der Schweizerischen Verordnung des UVEK (HKSV) vom 1. November 2017 |
authentication of Investment- and production data over den proof of the fuels and of the material of electricity according to of the swiss regulation of UVEK (HKSV) from 1. november 2017 |
D-ZE-14153-01-01 Scope
TÜV SÜD Industrie Service GmbH Zertifizierungsstelle für Fliegende Bauten, Windenergieanlagen, Klima und Energie Westendstraße 199; 80686
München
|
Bayern
+49 89 571 1090
+49 89 5791 2355
volker.rother @ tuev-sued.de
|
A07, B07, B25, B27, B29, B40, B42, B70, B71, M25, Anlage |
Fliegende Bauten, Vergnügungs-, Freizeit- und Spielanlagen |
flying buildings, Vergnügungs-, recreation- and game systems |
Search to
Search text - Field number = 'B71' Type of Accreditation='ALL' Location='ALL' Field Calibration='ALL' Field Testing (Tests)='ALL' Field Testing, Certification for Products (Products, Objects)='ALL' Field Certification for Persons='ALL' Field Certification for Managementsystem (Objects)='ALL' Field Certification for Managementsystem 2='ALL' Field Certification for the categories requested LSMS='ALL' Field European legislation='ALL' Field National legislation='ALL' Field Scopes of accreditation='ALLE' Additional output from Scope ? German and English
Case sensitivity? No
|
|